High and Low Alternation Test Chamber
Features:
High and Low Alternation Test Chamber provides a wide rang of industries including electronic parts such as aerospace products, information and electronic instrumentation, materials, electrical, a variety of electronic components in the high and low temperature environment, testing its performance
Description:The box body is processed shape using CNC machine tool, beautiful appearance,and uses no reaction door handles, easy to operate, safe and reliable.Adopted built-in fluorescent lamp,the rectangular viewing window consists of glass with a heat generator,which prevents blur and saves wiper operation so that you can always observe the test under the best conditions.Available in Chinese and English LCD touch screen,easy operation and program.Able to display the relative data and information of the whole operating system in running monde,graphic display,precautions,maintenance and trouble shooting.The siracco fan motor provides greater cyclic airflow to avoid dead corner in the chamber,so as to obtain a uniform distribution of temperature and humidity.The heating, cooling system completely independent can improve efficiency, reduce cost of test , increase life expectancy and reduce the failure rate Standard:
GB/T10589-1989: Technical Conditon of Low Temperature Test ChamberGB/T10592-1989:Technical Conditon of High & Low Temperature Test Chamber
Specifications 0ºC ~ +100(150ºC)
Model | THC-80AG | THC-150AG | THC-225AG | THC-416AG | THC-800AG | THC-1000AG | |
Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
H | 500 | 600 | 750 | 850 | 1000 | 1000 | |
D | 400 | 500 | 600 | 700 | 800 | 1000 | |
Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | |
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | |
Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | |
System | Balanced Temperature Control System | |
Environment temp.&humi.range | +5ºC ~ +35ºC / <85%RH |
Temp.range | -0ºC ~ +100(150ºC) (A=0ºC B=-20ºC C=-40ºC D=-70ºC optional) |
Temp.fluctuation | ≤0.5ºC |
Temp.uniformity | ≤2.0ºC |
Temp.stability | ±0.2ºC | ±1.5ºC |
Heating up time | 0ºC ~ +100ºC within 20 min |
Pull down time | 20ºC ~ 0ºC within 20 min |
Power | AC220V/380V,50/60HZ |
Exterior material | Cold rolled plate paint |
Interior material | Stainless steel plate |
Insulation | Polyurethane;fire retardant;100k insulation rockwool |
Refrigeration system | Hermetic compressor, single stage refrigeration system |
Heating system | Stainless steel thermal heaters |
Controller | TEMI-880 Touch panel |
Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm |
Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets |
Notes:
(1) At 20ºC Cambient temperature or 25ºC water temperature and non-loaded.
(2)The sensor should be located at a distance of 1/6 of the interior dimension from the interior chamber wall.
(3)The above specifications are for reference only,the actual specifications for the main quotaion.
(4)Can according to customer requirements of size, special order.
Specifications -20ºC ~ +100(150ºC)
Model | THC-80BG | THC-150BG | THC-225BG | THC-416BG | THC-800BG | THC-1000BG | |
Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
H | 500 | 600 | 750 | 850 | 1000 | 1000 | |
D | 400 | 500 | 600 | 700 | 800 | 1000 | |
Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | |
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | |
Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | |
System | Balanced Temperature Control System | |
Environment temp.&humi.range | +5ºC ~ +35ºC / <85%RH |
Temp.range | -20ºC ~ +100(150ºC) (A=0ºC B=-20ºC C=-40ºC D=-70ºC optional) |
Temp.fluctuation | ≤0.5ºC |
Temp.uniformity | ≤2.0ºC |
Temp.stability | ±0.2ºC | ±1.5ºC |
Heating up time | -20ºC ~ +100ºC within 35 min |
Pull down time | 20ºC ~ -20ºC within 45 min |
Power | AC220V/380V,50/60HZ |
Exterior material | Cold rolled plate paint |
Interior material | Stainless steel plate |
Insulation | Polyurethane;fire retardant;100k insulation rockwool |
Refrigeration system | Hermetic compressor,cascade refrigeration system |
Heating system | Stainless steel thermal heaters |
Controller | TEMI-880 Touch panel |
Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm |
Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets |
Notes:
(1) At 20ºC Cambient temperature or 25ºC water temperature and non-loaded.
(2)The sensor should be located at a distance of 1/6 of the interior dimension from the interior chamber wall.
(3)The above specifications are for reference only,the actual specifications for the main quotaion.
(4)Can according to customer requirements of size, special order.
Specifications -40ºC ~ +100(150ºC)
Model | THC-80CG | THC-150CG | THC-225CG | THC-416CG | THC-800CG | THC-1000CG | |
Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
H | 500 | 600 | 750 | 850 | 1000 | 1000 | |
D | 400 | 500 | 600 | 700 | 800 | 1000 | |
Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | |
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | |
Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | |
System | Balanced Temperature Control System | |
Environment temp.&humi.range | +5ºC ~ +35ºC / <85%RH |
Temp.range | -40ºC ~ +100(150ºC) (A=0ºC B=-20ºC C=-40ºC D=-70ºC optional) |
Temp.fluctuation | ≤0.5ºC |
Temp.uniformity | ≤2.0ºC |
Temp.stability | ±0.2ºC | ±1.5ºC |
Heating up time | -40ºC ~ +100ºC within 40 min |
Pull down time | 20ºC ~ -40ºC within 60 min |
Power | AC220V/380V,50/60HZ |
Exterior material | Cold rolled plate paint |
Interior material | Stainless steel plate |
Insulation | Polyurethane;fire retardant;100k insulation rockwool |
Refrigeration system | Hermetic compressor,cascade refrigeration system |
Heating system | Stainless steel thermal heaters |
Controller | TEMI-880 Touch panel |
Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm |
Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets |
Notes:
(1) At 20ºC Cambient temperature or 25ºC water temperature and non-loaded.
(2)The sensor should be located at a distance of 1/6 of the interior dimension from the interior chamber wall.
(3)The above specifications are for reference only,the actual specifications for the main quotaion.
(4)Can according to customer requirements of size, special order.
Specifications -70ºC ~ +100(150ºC)
Model | THC-80DG | THC-150DG | THC-225DG | THC-416DG | THC-800DG | THC-1000DG | |
Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
H | 500 | 600 | 750 | 850 | 1000 | 1000 | |
D | 400 | 500 | 600 | 700 | 800 | 1000 | |
Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | |
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | |
Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | |
System | Balanced Temperature Control System | |
Environment temp.&humi.range | +5ºC ~ +35ºC / <85%RH |
Temp.range | -70ºC ~ +100(150ºC) (A=0ºC B=-20ºC C=-40ºC D=-70ºC optional) |
Temp.fluctuation | ≤0.5ºC |
Temp.uniformity | ≤2.0ºC |
Temp.stability | ±0.2ºC | ±1.5ºC |
Heating up time | -70ºC ~ +100ºC within 60 min |
Pull down time | 20ºC ~ -70ºC within 90 min |
Power | AC220V/380V,50/60HZ |
Exterior material | Cold rolled plate paint |
Interior material | Stainless steel plate |
Insulation | Polyurethane;fire retardant;100k insulation rockwool |
Refrigeration system | Hermetic compressor,cascade refrigeration system |
Heating system | Stainless steel thermal heaters |
Controller | TEMI-880 Touch panel |
Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm |
Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets |
Notes:
(1) At 20ºC Cambient temperature or 25ºC water temperature and non-loaded.
(2)The sensor should be located at a distance of 1/6 of the interior dimension from the interior chamber wall.
(3)The above specifications are for reference only,the actual specifications for the main quotaion.
(4)Can according to customer requirements of size, special order.